editors
60
edits
(Created page with "== Notes == === CO2 === 20 crew - 0 passengers - 0 CO2 Scrubber - 0 Medium Tank - 0 tiles pipe - x10 speed: co2 quantity in the atmosphere at start of measurement 400, co2 quantity after 60 seconds 1179 20 crew - 0 passengers - 1 CO2 Scrubber - 1 Medium Tank - 3 tiles pipe - x10 speed: tank quantity at start of measurement 600, tank quantity after 60 seconds 1377 20 crew - 0 passengers - 2 CO2 Scrubber - 1 Medium Tank - 5 tiles pipe - x10 speed: tank quantity at start...") |
No edit summary |
||
Line 10: | Line 10: | ||
==> 20 crew exhales ~778 CO2 per 600 seconds ==> 1 crew exhales ~0,065 CO2/s or ~3,9 CO2/min | ==> 20 crew exhales ~778 CO2 per 600 seconds ==> 1 crew exhales ~0,065 CO2/s or ~3,9 CO2/min | ||
==> tanks, pipes and scrubbers don't influence CO2 | ==> tanks, pipes and scrubbers don't influence CO2 buildup | ||
suits on does not prevent co2 buildup! | |||
suits on | |||
49% atmosphere lowest possible value | 49% atmosphere lowest possible value | ||
at 49% atmosphere, | at 49% atmosphere, no more co2 is introduced | ||
air reprocessor | co2 scrubber stores 20 co2 | ||
air reprocessor | air reprocessor stores 25 co2 in ~9,3 s and produces 25 o2 in ~8,5 s during startup/shutdown | ||
air reprocessor produces ~ 2,5 co2/s during normal operation | |||
oxygen maker stores 24 h2o in ~10 s and produces 24 o2 in ~10 s during startup/shutdown | |||
oxygen maker produces uses ~2 h2o/s and produces ~2 o2/s during normal operation |