Eichi

Joined 2 October 2022
89 bytes added ,  09:48, 14 October 2022
no edit summary
No edit summary
No edit summary
Line 8: Line 8:
stored means o2 in the air
stored means o2 in the air


multiple airducts use more o2 than necessary. cause is unknown
<s>multiple airducts use more o2 than necessary. cause is unknown</s>


*1 crew exhales ~3,87 co2/min or ~0,064 co2/s
*1 crew exhales ~3,87 co2/min or ~0,064 co2/s
*1 crew needs ~4 o2/min or ~0,067 o2/s
*1 crew needs ~4 o2/min or ~0,067 o2/s
*1 crew produces ~1,9 sewage/min or ~0,032 sewage/s if cabin available
*1 crew produces ~1,9 sewage/min or ~0,032 sewage/s if cabin available
*co2 scrubber stores 20 co2
*<s>co2 scrubber stores 20 co2</s>
*co2 scrubber scrubs ~6,5 co2/s
*<s>co2 scrubber scrubs ~6,5 co2/s</s>
**=> ~ 1 co2 scrubber per 100 crew
**<s>=> ~ 1 co2 scrubber per 100 crew</s>
*airduct raises the atmosphere by 10 o2/s
*<s>airduct raises the atmosphere by 10 o2/s</s>
**==> ~1 airduct per 150 crew
**<s>==> ~1 airduct per 150 crew</s>
*<s>air reprocessor stores 25 co2 in ~9,3 s and produces 25 o2 in ~8,5 s during startup/shutdown</s>
*<s>air reprocessor stores 25 co2 in ~9,3 s and produces 25 o2 in ~8,5 s during startup/shutdown</s>
*<s>air reprocessor converts ~2,5 co2/s to ~2,5 o2/s during normal operation</s>
*<s>air reprocessor converts ~2,5 co2/s to ~2,5 o2/s during normal operation</s>
*oxygen maker stores 24 h2o in ~10 s and produces 24 o2 in ~10 s during startup/shutdown
*<s>oxygen maker stores 24 h2o in ~10 s and produces 24 o2 in ~10 s during startup/shutdown</s>
*oxygen maker converts ~2 h2o/s to ~2 o2/s during normal operation
*<s>oxygen maker converts ~2 h2o/s to ~2 o2/s during normal operation</s>
*water purifier stores 18 waste water in ~7 s and produces 18 o2 in ~6,3 s during startup/shutdown
*<s>water purifier stores 18 waste water in ~7 s and produces 18 water in ~6,3 s during startup/shutdown</s>
*water purifier converts ~2 waste h2o/s to ~2 water/s during normal operation
*<s>water purifier converts ~2 waste h2o/s to ~2 water/s during normal operation</s>
*waste treatment machine stores 30 sewage and produces 2 compost in ~14,5 s and produces 27 waste h2o and 1 compost in ~10,8 s during startup/shutdown
*<s>waste treatment machine stores 30 sewage and produces 2 compost in ~14,5 s and produces 27 waste h2o and 1 compost in ~10,8 s during startup/shutdown</s>
*waste treatment machine converts ~2 sewage/s to ~1,8 waste water/s and ~0,2 compost/s during normal operation
*<s>waste treatment machine converts ~2 sewage/s to ~1,8 waste water/s and ~0,2 compost/s during normal operation</s>
*sewage pipe stores undefined ammounts of sewage
*sewage pipe stores undefined ammounts of sewage
*sewage pipe supplies 20 sewage/s
*sewage pipe supplies 20 sewage/s
**==> 1 sewage pipe per 625 people
**==> 1 sewage pipe per 625 people
*loader loads 20 1/s
*loader loads 20 1/s
*airduct uses/delivers as much o2 as needed by the crew/passengers up to
*<s>airduct uses/delivers as much o2 as needed by the crew/passengers</s>
*tanks an pipes have now limit for delivery
*tanks and pipes have now limit for delivery
editors
60

edits