User:Eichi: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(12 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
== Notes == | == Notes == | ||
suits on does not prevent co2 buildup! | |||
49% atmosphere lowest possible value | |||
99% atmosphere highest possible value | |||
at 49% atmosphere, no more co2 is introduced | |||
stored means o2 in the air | |||
<s>multiple airducts use more o2 than necessary. cause is unknown</s> | |||
*1 crew exhales ~3,87 co2/min or ~0,064 co2/s | |||
*1 crew needs ~4 o2/min or ~0,067 o2/s | |||
*1 crew produces ~1,9 sewage/min or ~0,032 sewage/s if cabin available | |||
*<s>co2 scrubber stores 20 co2</s> | |||
*<s>co2 scrubber scrubs ~6,5 co2/s</s> | |||
**<s>=> ~ 1 co2 scrubber per 100 crew</s> | |||
*<s>airduct raises the atmosphere by 10 o2/s</s> | |||
co2 scrubber | **<s>==> ~1 airduct per 150 crew</s> | ||
air reprocessor stores 25 co2 in ~9,3 s and produces 25 o2 in ~8,5 s during startup/shutdown | *<s>air reprocessor stores 25 co2 in ~9,3 s and produces 25 o2 in ~8,5 s during startup/shutdown</s> | ||
air reprocessor | *<s>air reprocessor converts ~2,5 co2/s to ~2,5 o2/s during normal operation</s> | ||
oxygen maker stores 24 h2o in ~10 s and produces 24 o2 in ~10 s during startup/shutdown | *<s>oxygen maker stores 24 h2o in ~10 s and produces 24 o2 in ~10 s during startup/shutdown</s> | ||
oxygen maker produces | *<s>oxygen maker converts ~2 h2o/s to ~2 o2/s during normal operation</s> | ||
*<s>water purifier stores 18 waste water in ~7 s and produces 18 water in ~6,3 s during startup/shutdown</s> | |||
*<s>water purifier converts ~2 waste h2o/s to ~2 water/s during normal operation</s> | |||
*<s>waste treatment machine stores 30 sewage and produces 2 compost in ~14,5 s and produces 27 waste h2o and 1 compost in ~10,8 s during startup/shutdown</s> | |||
*<s>waste treatment machine converts ~2 sewage/s to ~1,8 waste water/s and ~0,2 compost/s during normal operation</s> | |||
*<s>sewage pipe stores undefined ammounts of sewage</s> | |||
*<s>sewage pipe supplies 20 sewage/s</s> | |||
**<s>==> 1 sewage pipe per 625 people</s> | |||
*<s>loader loads 20 1/s</s> | |||
*<s>airduct uses/delivers as much o2 as needed by the crew/passengers</s> | |||
*<s>tanks and pipes have now limit for delivery</s> |
Latest revision as of 10:03, 14 October 2022
Notes[edit | edit source]
suits on does not prevent co2 buildup!
49% atmosphere lowest possible value
99% atmosphere highest possible value
at 49% atmosphere, no more co2 is introduced
stored means o2 in the air
multiple airducts use more o2 than necessary. cause is unknown
- 1 crew exhales ~3,87 co2/min or ~0,064 co2/s
- 1 crew needs ~4 o2/min or ~0,067 o2/s
- 1 crew produces ~1,9 sewage/min or ~0,032 sewage/s if cabin available
co2 scrubber stores 20 co2co2 scrubber scrubs ~6,5 co2/s=> ~ 1 co2 scrubber per 100 crew
airduct raises the atmosphere by 10 o2/s==> ~1 airduct per 150 crew
air reprocessor stores 25 co2 in ~9,3 s and produces 25 o2 in ~8,5 s during startup/shutdownair reprocessor converts ~2,5 co2/s to ~2,5 o2/s during normal operationoxygen maker stores 24 h2o in ~10 s and produces 24 o2 in ~10 s during startup/shutdownoxygen maker converts ~2 h2o/s to ~2 o2/s during normal operationwater purifier stores 18 waste water in ~7 s and produces 18 water in ~6,3 s during startup/shutdownwater purifier converts ~2 waste h2o/s to ~2 water/s during normal operationwaste treatment machine stores 30 sewage and produces 2 compost in ~14,5 s and produces 27 waste h2o and 1 compost in ~10,8 s during startup/shutdownwaste treatment machine converts ~2 sewage/s to ~1,8 waste water/s and ~0,2 compost/s during normal operationsewage pipe stores undefined ammounts of sewagesewage pipe supplies 20 sewage/s==> 1 sewage pipe per 625 people
loader loads 20 1/sairduct uses/delivers as much o2 as needed by the crew/passengerstanks and pipes have now limit for delivery