User:Eichi: Difference between revisions

From The Last Starwiki
Jump to navigation Jump to search
(Created page with "== Notes == === CO2 === 20 crew - 0 passengers - 0 CO2 Scrubber - 0 Medium Tank - 0 tiles pipe - x10 speed: co2 quantity in the atmosphere at start of measurement 400, co2 quantity after 60 seconds 1179 20 crew - 0 passengers - 1 CO2 Scrubber - 1 Medium Tank - 3 tiles pipe - x10 speed: tank quantity at start of measurement 600, tank quantity after 60 seconds 1377 20 crew - 0 passengers - 2 CO2 Scrubber - 1 Medium Tank - 5 tiles pipe - x10 speed: tank quantity at start...")
 
No edit summary
 
(13 intermediate revisions by the same user not shown)
Line 1: Line 1:
== Notes ==
== Notes ==
=== CO2 ===
suits on does not prevent co2 buildup!


20 crew - 0 passengers - 0 CO2 Scrubber - 0 Medium Tank - 0 tiles pipe - x10 speed: co2 quantity in the atmosphere at start of measurement 400, co2 quantity after 60 seconds 1179
49% atmosphere lowest possible value
 
20 crew - 0 passengers - 1 CO2 Scrubber - 1 Medium Tank - 3 tiles pipe - x10 speed: tank quantity at start of measurement 600, tank quantity after 60 seconds 1377
 
20 crew - 0 passengers - 2 CO2 Scrubber - 1 Medium Tank - 5 tiles pipe - x10 speed: tank quantity at start of measurement 600, tank quantity after 60 seconds 1377


99% atmosphere highest possible value


==> 20 crew exhales ~778 CO2 per 600 seconds ==> 1 crew exhales ~0,065 CO2/s or ~3,9 CO2/min
at 49% atmosphere, no more co2 is introduced
==> tanks, pipes and scrubbers don't influence CO2 build up
 
CO2 scrubbing
20 crew - 0 passengers - 1 CO2 Scrubber - 1 Medium Tank - 3 tiles pipe - x10 speed: co2 quantity in the atmosphere at start of measurement 1000, co2 quantity after 60 seconds ; co2 quantity in the tank at start of measurement , co2 quantity after 60 seconds
 
suits on -> 2880 -> 60 sec -> 0
 
49% atmosphere lowest possible value
at 49% atmosphere, there is no more co2 introduced to the air


co2 scrubber capacity: 1164 start -> 1184 end --> CO2 scrubbers store 20 co2
stored means o2 in the air


air reprocessor w/ start up: 1184 co2, 5930 o2, 1x speed, 60 sec -> 1028 co2, 6085 o2 ~> 2,6 co2/s -> 2,6 o2/s
<s>multiple airducts use more o2 than necessary. cause is unknown</s>
air reprocessor w/o start up: 1000 co2, 6115 o2, 1x speed, 60 sec -> 850 co2, 6265 o2 ~> 2,5 co2/s, 2,5 o2/s
*1 crew exhales ~3,87 co2/min or ~0,064 co2/s
air reprocessor storage: 796 co2, 6315 o2, 1x speed -> 6,5 sec, 776 co2 -> 6,3 sec, 6335 o2 ~> 20 co2, ~3 co2/s, 20 o2, ~3 o2/sec
*1 crew needs ~4 o2/min or ~0,067 o2/s
*1 crew produces ~1,9 sewage/min or ~0,032 sewage/s if cabin available
*<s>co2 scrubber stores 20 co2</s>
*<s>co2 scrubber scrubs ~6,5 co2/s</s>
**<s>=> ~ 1 co2 scrubber per 100 crew</s>
*<s>airduct raises the atmosphere by 10 o2/s</s>
**<s>==> ~1 airduct per 150 crew</s>
*<s>air reprocessor stores 25 co2 in ~9,3 s and produces 25 o2 in ~8,5 s during startup/shutdown</s>
*<s>air reprocessor converts ~2,5 co2/s to ~2,5 o2/s during normal operation</s>
*<s>oxygen maker stores 24 h2o in ~10 s and produces 24 o2 in ~10 s during startup/shutdown</s>
*<s>oxygen maker converts ~2 h2o/s to ~2 o2/s during normal operation</s>
*<s>water purifier stores 18 waste water in ~7 s and produces 18 water in ~6,3 s during startup/shutdown</s>
*<s>water purifier converts ~2 waste h2o/s to ~2 water/s during normal operation</s>
*<s>waste treatment machine stores 30 sewage and produces 2 compost in ~14,5 s and produces 27 waste h2o and 1 compost in ~10,8 s during startup/shutdown</s>
*<s>waste treatment machine converts ~2 sewage/s to ~1,8 waste water/s and ~0,2 compost/s during normal operation</s>
*<s>sewage pipe stores undefined ammounts of sewage</s>
*<s>sewage pipe supplies 20 sewage/s</s>
**<s>==> 1 sewage pipe per 625 people</s>
*<s>loader loads 20 1/s</s>
*<s>airduct uses/delivers as much o2 as needed by the crew/passengers</s>
*<s>tanks and pipes have now limit for delivery</s>

Latest revision as of 10:03, 14 October 2022

Notes[edit | edit source]

suits on does not prevent co2 buildup!

49% atmosphere lowest possible value

99% atmosphere highest possible value

at 49% atmosphere, no more co2 is introduced

stored means o2 in the air

multiple airducts use more o2 than necessary. cause is unknown

  • 1 crew exhales ~3,87 co2/min or ~0,064 co2/s
  • 1 crew needs ~4 o2/min or ~0,067 o2/s
  • 1 crew produces ~1,9 sewage/min or ~0,032 sewage/s if cabin available
  • co2 scrubber stores 20 co2
  • co2 scrubber scrubs ~6,5 co2/s
    • => ~ 1 co2 scrubber per 100 crew
  • airduct raises the atmosphere by 10 o2/s
    • ==> ~1 airduct per 150 crew
  • air reprocessor stores 25 co2 in ~9,3 s and produces 25 o2 in ~8,5 s during startup/shutdown
  • air reprocessor converts ~2,5 co2/s to ~2,5 o2/s during normal operation
  • oxygen maker stores 24 h2o in ~10 s and produces 24 o2 in ~10 s during startup/shutdown
  • oxygen maker converts ~2 h2o/s to ~2 o2/s during normal operation
  • water purifier stores 18 waste water in ~7 s and produces 18 water in ~6,3 s during startup/shutdown
  • water purifier converts ~2 waste h2o/s to ~2 water/s during normal operation
  • waste treatment machine stores 30 sewage and produces 2 compost in ~14,5 s and produces 27 waste h2o and 1 compost in ~10,8 s during startup/shutdown
  • waste treatment machine converts ~2 sewage/s to ~1,8 waste water/s and ~0,2 compost/s during normal operation
  • sewage pipe stores undefined ammounts of sewage
  • sewage pipe supplies 20 sewage/s
    • ==> 1 sewage pipe per 625 people
  • loader loads 20 1/s
  • airduct uses/delivers as much o2 as needed by the crew/passengers
  • tanks and pipes have now limit for delivery